BRAND PIPETTE PACKAGE 2 Transferpette S Adjustable Automatic Pipette Set 0.5-10 µL, 10-100 µL, 20-200 µL, 100-1000 µL, 500-5000 µL, 6 Stand
Description;
BRAND's Transferpette® S is the same high-quality pipette customers have come to expect. A lightweight yet robust instrument offering a high degree of accuracy and precision, the Transferpette® S now offers newly enhanced features that make working easier and more efficient.
- With its new handle geometry, Transferpette® S provides a comfortable grip regardless of hand size and when working with the right or left hand. Also, true one-handed operation means that the grip does not change or the sample is placed on the ground to adjust the volume level.
- The newly designed volume setting brake is easy to use and clearly shows that the pipette is secured against accidental volume changes.
- An even thinner shaft makes working with narrow tubes and bottles more manageable - save more of your sample and the shaft coupling to the handle has been redesigned to improve ergonomics and make cleaning easier.
- Color-coded pipette highlights for tip selection are even clearer.
Transferpette® S Single Channel Fixed Volume and Transferpette® S 8- and 12- Multichannel Pipettes are also available.
- One-handed volume adjustment with brake to protect against accidental volume changes
- 12.5 mm piston stroke length is the shortest of any leading pipette
- Easy Calibration™ technology provides fast, easy, in-lab calibration adjustments without tools
- The four-digit volume display is always visible
- Universal tip cone fits most premium manufacturers' tips
- Fully and repeatedly autoclavable at 121 °C / 250 °F (20 minutes)
Transferpette® S Single Channel Pipettes are supplied with performance certificate, instruction manual, rack mount and a two-year warranty.
Usage Limitations - This device is designed for pipetting liquids within the following limitations:
- Use instrument and reagent between +15 °C and +40 °C (59 °F to 104 °F)
- Steam pressure up to 500 mbar
- Viscosity: 260 mPa/s (260 cps)
Exception Handling- This instrument cannot be used with:
- Liquids incompatible with polypropylene
- Liquids not compatible with polycarbonate (view window)
- Liquids incompatible with FKM and polyether ether ketone (PEEK)
- Liquids incompatible with polyvinylidene fluoride
- Liquids incompatible with polyphenylsulfite (PPS) (in an adjustable 50 µl instrument)
- Liquids with very high vapor pressure
Technical data;
|
|
|
|
|
|
Code number |
Capacity |
Model |
A* ≤ ± % |
CV* ≤ % |
Lower Limit |
705868 |
0,1-1 µL |
D-1 |
2 |
1.2 |
0,001 µL |
705869 |
0,1-2,5 µL |
D-2.5 |
1.4 |
0.7 |
0,002 µL |
705870 |
0,5-10 µL |
D-10 |
1 |
0,5 |
0,01 µL |
705872 |
2-20 µL |
D-20 |
0.8 |
0.4 |
0,02 µL |
705873 |
5-50 µL |
D-50 |
0.8 |
0.3 |
0,05 µL |
705874 |
10-100 µL |
D-100 |
0.6 |
0.2 |
0,1 µL |
705878 |
20-200 µL |
D-200 |
0.6 |
0.2 |
0,2 uL |
705880 |
100-1000 µL |
D-1000 |
0.6 |
0.2 |
1 µL |
705882 |
500-5000 µL (0,5-5 mL) |
D-5000 |
0.6 |
0.2 |
5 µL |
705884 |
1000-10000 µL (1-10 mL) |
D-10000 |
0.6 |
0.2 |
10 µL |
|
|
|
|
|
|
A*=Accuracy, CV*=Coefficient of Variation
*Accuracy value and coefficient of variation are final test values referring to distilled water with given nominal volume, device and ambient temperature (20°C/68°F) in equilibrium and smooth operation.